S-8211E
Features
(1) High-accuracy voltage detection circuit
- Overcharge detection voltage
3.6 V to 4.5 V (5 m V step)
Accuracy ±25 m V (+25°C)
- Overcharge release voltage
3.5 V to 4.4 V- 1
Accuracy ±30 m V (- 5°C to +55°C) Accuracy ±50 m V
- Overdischarge detection voltage
- Overdischarge release voltage
2.0 V to 3.0 V (10 m V step) 2.0 V to 3.4 V- 2
Accuracy ±50 m V Accuracy ±100 m V
(2) Detection delay times are generated by an internal circuit
(external capacitors are unnecessary)
Accuracy ±20%
(3) Wide operating temperature range
- 40°C to +85°C
(4) Low current consumption
- During operation
3.0 μA typ., 5.5 μA max. (+25°C)
- During overdischarge
2.0 μA typ., 3.5 μA max. (+25°C)
(5) Output logic of CO pin is selectable. (6) Lead-free, Sn 100%, halogen-free- 3
Active “H”, Active “L”
- 1. Overcharge release voltage = Overcharge detection voltage
- Overcharge hysteresis voltage (Overcharge hysteresis voltage can be selected as 0 V or from a range of 0.1 V to 0.4 V in 50 m V...