S-8211C
Features
- High-accuracy voltage detection circuit
Overcharge detection voltage
3.9 V to 4.5 V (5 m V step)
Accuracy 25 m V (Ta = 25°C)
Overcharge release voltage
3.8 V to 4.43 V- 1 P
Accuracy 30 m V (Ta =
- 5°C to 55°C)
Accuracy
50 m V
Overdischarge detection voltage Overdischarge release voltage
2.0 V to 3.0 V (10 m V step) 2.0 V to 3.4 V- 2
Accuracy 50 m V
Accuracy
100 m V
Discharge overcurrent detection voltage
0.05 V to 0.30 V (10 m V step) Accuracy 15 m V
Load short-circuiting detection...