S-8204A
Features
- High-accuracy voltage detection function for each cell
Overcharge detection voltage n (n = 1 to 4) Overcharge release voltage n (n = 1 to 4)
3.8 V to 4.6 V (50 m V step) 3.6 V to 4.6 V- 1
Accuracy ±25 m V Accuracy ±50 m V
Overdischarge detection voltage n (n = 1 to 4) 2.0 V to 3.0 V (100 m V step) Overdischarge release voltage n (n = 1 to 4) 2.0 V to 3.4 V- 2
Accuracy ±80 m V Accuracy ±100 m V
- Discharge overcurrent detection function in 3-step
Discharge overcurrent detection voltage 1
0.05 V to 0.30 V (50 m V step) Accuracy ±15 m V
Discharge overcurrent detection voltage 2
0.5 V (fixed)
Accuracy ±100 m V
Load short-circuit detection voltage
1.0 V (fixed)
Accuracy ±300 m V
- Charge overcurrent detection function
Charge overcurrent detection voltage
- 0.25 V to
- 0.05 V (50 m V step) Accuracy ±30 m V
- Settable by external capacitor; overcharge detection delay time, overdischarge detection delay time, discharge overcurrent detection delay time 1, discharge overcurrent...