Features
- High-accuracy voltage detection circuit
Overcharge detection voltage Overcharge release voltage
3.50 V to 5.00 V (5 m V step) 3.10 V to 4.95 V- 1
Accuracy ±20 m V Accuracy ±50 m V
- Detection delay time is generated only by an internal circuit (external capacitors are unnecessary).
- Output logic is selectable:
Active "H", active "L"
- Output form is selectable:
CMOS output, Nch open-drain output
- Wide operation temperature range
Ta =
- 40°C to +85°C
- Low current consumption
During operation:
1.5 μA typ., 3.0 μA max. (Ta = +25°C)
- Lead-free (Sn 100%), halogen-free
- 1. Overcharge release voltage = Overcharge detection voltage
- Overcharge hysteresis voltage (Overcharge hysteresis voltage can be selected from a range of 0.05 V to 0.4 V in 50 m V step.)
- Applications
- Lithium-ion rechargeable battery pack
- Lithium polymer rechargeable battery pack
- Packages
- SNT-6A
- HSNT-6 (1212)