S-8209B
Features
(1) High-accuracy voltage detection circuit
- 1 3.55 V to 4.40 V (5 m V step)
- Overcharge detection voltage
- 1
- Overcharge release voltage 3.50 V to 4.40 V- 2
- Cell-balance detection voltage- 1 3.55 V to 4.40 V (5 m V step)- 3
- 1
- Cell-balance release voltage 3.50 V to 4.40 V- 4
- Overdischarge detection voltage 2.0 V to 3.0 V (10 m V step)
- 5
- Overdischarge detection voltage 2.0 V to 3.4 V Settable delay time by external capacitor for output pin Control charging, discharging, cell-balance by CTLC, CTLD pins Two types of cell-balance function; charge/discharge- 6 Wide range of operation temperature
- 40°C to +85°C Low current consumption 7.0 µA max. Small package SNT-8A, 8-Pin TSSOP Lead-free product Accuracy ±25 m V Accuracy ±50 m V Accuracy ±25 m V Accuracy ±50 m V Accuracy ±50 m V Accuracy ±100 m V
(2) (3) (4) (5) (6) (7) (8)
- 1. Regarding selection of overcharge detection voltage, overcharge release voltage, cell-balance detection voltage and cell-balance release voltage, refer to...