S-5852A
Features
- Temperature accuracy- 1:
±0.5°C typ. / ±1.0°C max. (Ta = 0°C to +65°C)
±0.5°C typ. / ±1.0°C max. (Ta = +75°C to +95°C)
- Temperature resolution:
0.5°C, 0.25°C, 0.125°C, 0.0625°C
(Selectable by the resolution register)
- Temperature sample rate:
7 samples / s min.
- Selectable hysteresis width: No hysteresis, 1.5°C, 3.0°C, 6.0°C
- Current consumption:
Shutdown mode at serial bus non-active: 0.3 μA typ., 3.0 μA max.
Active mode at serial bus non-active:
40 μA typ., 100 μA max.
- Operation voltage range:
1.7 V to 3.6 V
- Operation frequency:
- Thermostat function:
1.0 MHz max. (VDD = 2.2 V to 3.6 V) 400 k Hz max. (VDD = 1.7 V to 2.2 V) Dual trip mode, single trip mode, OFF
(Selectable by the configuration register)
- Noise suppression:
Schmitt trigger and noise filter on input pins (SCL, SDA)
- Operation temperature range: Ta =
- 40°C to +125°C
- Lead-free (Sn 100%), halogen-free
- 1. The option can be selected.
- Applications
- Solid state drive
- Hard...