S-8209A
Features
- High-accuracy voltage detection circuit
Overcharge detection voltage- 1
3.55 V to 4.40 V (5 m V step)
Overcharge release voltage- 1
3.50 V to 4.40 V- 2
Cell-balance detection voltage- 1
3.55 V to 4.40 V (5 m V step)- 3
Cell-balance release voltage- 1
3.50 V to 4.40 V- 4
Overdischarge detection voltage
2.0 V to 3.0 V (10 m V step)
Overdischarge release voltage
2.0 V to 3.4 V- 5
- Settable delay time by external capacitor for output pin
- Control charging, discharging, cell-balance by CTLC pin and CTLD pin
- Two types of cell-balance function; charge / discharge- 6
- Wide range of operation temperature
Ta =
- 40°C to +85°C
- Low current consumption
7.0 μA max.
- Lead-free, Sn 100%, halogen-free- 7
Accuracy ±25 m V Accuracy ±50 m V Accuracy ±25 m V Accuracy ±50 m V Accuracy ±50 m V Accuracy ±100 m V
- 1. Regarding selection of overcharge detection voltage, overcharge release voltage, cell-balance detection voltage and cell-balance release voltage, refer to Remark 3 in "3....