S-8205A
Features
- High-accuracy voltage detection function for each cell
Overcharge detection voltage n (n = 1 to 5)
3.550 V to 4.500 V- 1 (50 m V step) Accuracy ±25 m V
Overcharge release voltage n (n = 1 to 5)
3.300 V to 4.500 V- 2
Accuracy ±50 m V
Overdischarge detection voltage n (n = 1 to 5)
2.000 V to 3.200 V- 1 (100 m V step) Accuracy ±80 m V
Overdischarge release voltage n (n = 1 to 5)
2.000 V to 3.400 V- 3
Accuracy ±100 m V
- Discharge overcurrent detection in 2-step
Discharge overcurrent detection voltage
0.050 V to 0.300 V- 4 (50 m V step) Accuracy ±15 m V
Short circuit detection voltage
0.500 V to 1.000 V- 4 (100 m V step) Accuracy ±100 m V
- Charge overcurrent detection
Charge overcurrent detection voltage
- 0.300 V to
- 0.050 V (50 m V step) Accuracy ±30 m V
- Settable by external capacitor; Overcharge detection delay time, Overdischarge detection delay time, Discharge overcurrent detection delay time, Charge overcurrent detection delay time
(Load short circuit detection...