Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
2 Hanbury Road Chelmsford Essex CM1 3AE United Kingdom T: +44 (0)1245-809110 F: +44 (0)1245-809112 E: sales.is@sgxsensortech.com www.sgxsensortech.com SGX-7H2S Datasheet Industrial Hydrogen Sulfide Sensor Application : Fixed Gas Detectors PERFORMANCE Typical Baseline Range…..<±0.5 ppm H2S equivalent Measurement Range ……...………………. 0 – 50 ppm Output Signal ……………...…… 1700 ± 400 nA / ppm Linearity …………………....…. .…………………. Linear Repeatability …………………...< ±1% H2S equivalent Response time, t90 ……….…. …………………... <40 s Maximum Overload …….…….………………. 500 ppm Long-term output drift …….…….……… <5% per annum Recommended Load Resistor ………….……... 10 ohms Warranty ………………………. .…………………. 2 year Resolution (Electronics dependent) ……….. < 0.1 ppm typical OPERATING CONDITIONS Temperature Range ….….…. ..