SGX-7CL2
SGX-7CL2 Datasheet
Industrial CL2 Sensor
PERFORMANCE Output signal Typical Baseline Range
(pure air)
T90 Response Time
Measurement Range
Maximum Overload
Linearity
Repeatability Remended Load Resistor Resolution (Electronics dependent)
1000 ± 300 n A / ppm ±0.2ppm CL2 equivalent
< 60 seconds 0
- 20 ppm 250 ppm Linear
< ±2% CL2 equivalent 33 ohms
0.1 ppm typical
OPERATING CONDITIONS Temperature Range
-20°C to +50°C
Pressure Range
Operating Humidity Range
800 to 1200 mbar 15% to 90% RH
LIFETIME Long Term Output Drift
Remended Storage Temp
Expected Operating Life
< 20% per annum 0°C to 20°C
> 12 months in air
SGX Europe Sp. Z o.o. Building 11 Ligocka St. 103, 40-568 Katowice, Poland
T: +48 (0) 32 438 4778
E: sales.is@sgxsensortech. .sgxsensortech.
OUTLINE
All dimensions are in mm All tolerances are ±0.15mm
INTRINSIC SAFETY DATA
Max at 150ppm
0.3 m A
Max o/c Voltage
1.3 V
Max s/c Current
<1.0 A
© SGX Sensortech 2012-2020
DS-0339 SGX-7CL2, Issue 1, 27-Mar-2020, Page...