Description
The HEF4047B consists of a gatable astable multivibrator incorporating logic techniques to permit positive or negative edge-triggered monostable multivibrator action with retriggering and external counting options.
Inputs include +TRIGGER, TRIGGER, ASTABLE, ASTABLE, RETRIGGER and MR (master reset).
Features
- 2.1 General.
- Monostable (one-shot) or astable (free-running) operation.
- True and complemented buffered outputs.
- Only one external resistor and capacitor required
NXP Semiconductors
HEF4047B
Monostable/astable multivibrator
2.2 Monostable multivibrator.
- Positive- or negative-edge triggering.
- Output pulse width independent of trigger pulse duration.
- Retriggerable option for pulse-width expansion.
- Long pulse width possible using small RC components
with externa.