AMC1106M05
Features
- 1 ±50-m V input voltage range optimized for current measurement with shunt resistors
- Manchester coded or uncoded bitstream options
- Excellent DC performance for high-precision sensing on system level:
- Offset error and drift: ±50 µV, ±1 µV/°C (max)
- Gain error and drift: ±0.2%, ±40 ppm/°C (max)
- 3.3-V operation for reduced power dissipation on both sides of the isolation barrier
- System-level diagnostic features
- High electromagnetic field immunity (see the ISO72x Digital Isolator Magnetic-Field Immunity application report)
- Safety-related certifications:
- 5657-VPK basic isolation per DIN VDE V 0884-
11: 2017-01
- 4000-VRMS isolation for 1 minute per UL1577
- CAN/CSA No. 5A-ponent acceptance service notice and DIN EN 61010-1 end equipment standard
2 Applications
Shunt-resistor-based current sensing in 3-phase electricity meters
3 Description
The AMC1106 is a precision, delta-sigma (ΔΣ) modulator with the output separated from the input circuitry by a capacitive...