T130CB-LC
Feature
:
- Peak Off-State Voltage from 90 to 360 Volts.
- Meet IEC61000-4-4 & -5 Industry Requirement.
- Provides Protection in Accordance with FCC Part 68, UL1459,Bellcore 1089, ITU-TK. 20 & K. 21.
- UL94V-0 Flammability Classification.
- ESD Protection >40 kilovolts.
- Low Capacitance for T1/E1 Trunk and Line Card Application.
- High Surge Current Capability.
SMB(DO-214AA)
Mechanical Data
- Case: JEDEC DO214AA. Molded Plastic Over Glass Passivated Junction
- Terminal: Solder Plated, Solderable per MIL-STD-750, Method 2026
- Standard Packaging: 12mm tape(EIA STD RS-481)
- Weight: 0.093 gram
SMB Outline Dimension
SMB Dim A B C D E G H J Min
3.30 4.06 1.96 0.15 5.00 0.10 0.76 2.00
Unit:mm
Max
3.94 4.80 2.21 0.31 5.59 0.20 1.52 2.62
.. http://.weitron..tw
WEITRON
1/3
Rev.A 29-Jan-07
T110AB-LC Thru T400AB-LC T110BB-LC Thru T400BB-LC T110CB-LC Thru T400CB-LC
Maximum Ratings
PART NUMBER MARKING CODE REPETITIVE MINIMUM SWITCHING SURGE HOLDING SWITCHING PEAK VOLTAGE RATINGS...