Datasheet4U Logo Datasheet4U.com

V23990-P84-A20 - Output Inverter Application

📥 Download Datasheet

Datasheet Details

Part number V23990-P84-A20
Manufacturer Vincotech
File Size 115.19 KB
Description Output Inverter Application
Datasheet download datasheet V23990-P84-A20 Datasheet

Full PDF Text Transcription

Click to expand full text
V23990-P84-A20 final data sheet flowPIM®1, 600V Output inverter application General conditions3 phase SPWM, Vgeon= 15 V Vgeoff=0V Rgon= 40 ohms Rgoff= 20 ohms www.DataSheet4U.com Figure 1. Typical avarage static loss as a function of output current Ploss=f(Iout) IGBT Ploss (W) Ploss (W) 32 28 24 20 16 12 8 4 Mi*cosfi=-1 0 0 5 10 15 20 Iout (A) 25 0 0 16 14 Figure 2. Typical avarage static loss as a function of output current FRED Ploss=f(Iout) Mi*cosfi=-1 12 10 8 6 4 2 Mi*cosfi=1 5 10 15 20 25 Iout (A) Conditions: Tj=125°C Modulation index * cosfi parameter Mi*cosfi from -1,00 to in 0,20 steps 1,00 Conditions: Tj=125°C Modulation index * cosfi parameter Mi*cosfi from -1,00 to in 0,20 steps 1,00 Figure 3.