Description
9 ENABLE/DISABLE S1 ENABLE/DISABLE S2 ENABLE/DISABLE S3 SIGNAL GROUND +5V@300mA AC POWER OK GENERAL SHUTDOWN N/C N/C
S2
1
NOTE: SET SCREW MAX TORQUE = 4.4 IN-LBS
2
NOTE:
DO NOT OPERATE WITHOUT EARTH GND
S1
1
L1 L2/N
MATING CONNECTOR: HOUSING: AMP P/N: 205204-4 TERMINALS: AMP P/N: 66506-9 SCREW LOCK: AMP P/N: 205980-4 CRIMP TOOL: AMP 58448-3
1 8.000 [203,20]
14 AWG WIRE 2.00 [50,80]
MBJ1 INPUT CONNECTIONS MBJ1-1 EARTH GROUND MBJ1-2 L2 / NEUTRAL MBJ1-3 L1
FOUR OUTPUT UNIT PICTURED (SEE
Features
- Near unity power factor EN61000-3-2 harmonic current compliance Low profile package Output power to 1,500W Up to 6 user specifiable outputs Universal AC input Power density up to 11W/in3 Integral cooling fans New “Autosense” feature Safety agency approvals: UL, CUL, TÜV, VDE, CE Marked
PFC Mini
12.20" x 6.00" x 1.75" 309,9 x 152,4 x 44,5 mm Up to 1,500W 1 to 6 Outputs
Overview
The PFC MicroS, PF.