S-1003
Features
- Detection voltage:
- Detection voltage accuracy:
- Current consumption:
- Operation voltage range:
- Hysteresis width:
- Manual reset function:
- Delay time accuracy:
- Output form:
- Operation temperature range:
- Lead-free (Sn 100%), halogen-free
1.2 V to 5.0 V (0.1 V step) ±1.0% (2.2 V ≤
- VDET ≤ 5.0 V) ±22 m V (1.2 V ≤
- VDET < 2.2 V) 500 n A typ. 0.95 V to 10.0 V 5% ± 2% MR pin logic active "L", active "H" ±15% (CD = 4.7 n F) Nch open-drain output (Active "L") CMOS output (Active "L") Ta =
- 40°C to +85°C
- Applications
- Power supply monitor for microputer and reset for CPU
- Constant voltage power supply monitor for TV, Blu-ray recorder and home appliance
- Power supply monitor for portable devices such as notebook PC, digital still camera and mobile phone
- Packages
- SOT-23-5
- SNT-6A
Seiko Instruments Inc.
MANUAL RESET BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING) HIGH-ACCURACY VOLTAGE DETECTOR
S-1003 Series
Rev.1.0_00
- Block Diagrams
1. Nch...