Datasheet4U Logo Datasheet4U.com

SFA0001-VF-RP - Switching Power-Supply

Datasheet Summary

Features

  • Build-in current limit protection, thermal shutdown protection. Built-in error-amp helps eliminate components at sensing stage such as shunt regulator. 3 Absolute maximum ratings 3-1 Absolute maximum ratings(Ta=25℃) Parameter Symbol Ratings Unit OCP terminal voltage VOCP -6~+6 V SS terminal voltage VSS -0.3~+9 V FB terminal voltage VFB -0.3~+6 V Input voltage for control part VCC 0~ 36 V Phase compensation terminal voltage VCOMP -0.3~+ 6 V Frequency setting terminal vo.

📥 Download Datasheet

Datasheet preview – SFA0001-VF-RP

Datasheet Details

Part number SFA0001-VF-RP
Manufacturer Sanken
File Size 1.02 MB
Description Switching Power-Supply
Datasheet download datasheet SFA0001-VF-RP Datasheet
Additional preview pages of the SFA0001-VF-RP datasheet.
Other Datasheets by Sanken

Full PDF Text Transcription

Click to expand full text
SANKEN ELECTRIC CO., LTD. 1 Scope The present specifications shall apply to switching power supply IC SFA0001-VF-RP 2 Outline Type Structure Semiconductor IC (Monolithic IC) Plastic package (Transfer mold) SFA0001-VF-RP Features Build-in current limit protection, thermal shutdown protection. Built-in error-amp helps eliminate components at sensing stage such as shunt regulator. 3 Absolute maximum ratings 3-1 Absolute maximum ratings(Ta=25℃) Parameter Symbol Ratings Unit OCP terminal voltage VOCP -6~+6 V SS terminal voltage VSS -0.3~+9 V FB terminal voltage VFB -0.3~+6 V Input voltage for control part VCC 0~ 36 V Phase compensation terminal voltage VCOMP -0.3~+ 6 V Frequency setting terminal voltage VFREQ -0.
Published: |