SGX-7H2S
2 Hanbury Road Chelmsford Essex CM1 3AE United Kingdom
T: +44 (0)1245-809110 F: +44 (0)1245-809112 E: sales.is@sgxsensortech. .sgxsensortech.
SGX-7H2S Datasheet Industrial Hydrogen Sulfide Sensor
Application : Fixed Gas Detectors
PERFORMANCE
Typical Baseline Range…..<±0.5 ppm H2S equivalent Measurement Range ……...………………. 0
- 50 ppm Output Signal ……………...…… 1700 ± 400 n A / ppm Linearity …………………....…. .…………………. Linear Repeatability …………………...< ±1% H2S equivalent Response time, t90 ……….…. …………………... <40 s Maximum Overload …….…….………………. 500 ppm Long-term output drift …….…….……… <5% per annum Remended Load Resistor ………….……... 10 ohms Warranty ………………………. .…………………. 2 year Resolution (Electronics dependent) ……….. < 0.1 ppm typical
OPERATING CONDITIONS
Temperature Range ….….…. ..………….. -30 to +50°C Operating Humidity....1..5
- 90% RH (non-condensing) Pressure range ……….…….…800 mbar to 1200 mbar Remended Storage Temperature..…...0°C to 20°C Expected Operating Life ….…………. <2 years (in...