Datasheet4U Logo Datasheet4U.com

BD9584F - EARTH LEAKAGE CURRENT DETECTOR

Description

BD9584F integrates leakage detector and amplifier.

Especially, it is suitable for high sensitivity and a highspeed operation use, and since the operating temperature range is wide, it can be used for various uses.

Key Specifications Operating supply voltage range: 8V to 20V Oper

Features

  • re fluctuation and high input sensitivity.
  • Wide operating temperature range.
  • Packages SOP8 W(Typ. ) x D(Typ. ) x H(Max. ) 5.00mm x 6.20mm x 1.71mm.

📥 Download Datasheet

Datasheet Details

Part number BD9584F
Manufacturer ROHM
File Size 514.09 KB
Description EARTH LEAKAGE CURRENT DETECTOR
Datasheet download datasheet BD9584F Datasheet
Other Datasheets by ROHM

Full PDF Text Transcription

Click to expand full text
Datasheet EARTH LEAKAGE CURRENT DETECTOR EARTH LEAKAGE CURRENT DETECTOR IC BD9584F ●General Description BD9584F integrates leakage detector and amplifier. Especially, it is suitable for high sensitivity and a highspeed operation use, and since the operating temperature range is wide, it can be used for various uses. ●Key Specifications ■ Operating supply voltage range: 8V to 20V ■ Operating temperature range: -20°C to +90°C ■ Supply current: 250μA(typ.) ■ Trip voltage: 6.4mV to 12.0mV ■ Output current ability(Ta=-20℃): 250μA(min.) ●Features ■ Small temperature fluctuation and high input sensitivity ■ Wide operating temperature range ●Packages SOP8 W(Typ.) x D(Typ.) x H(Max.) 5.00mm x 6.20mm x 1.