Click to expand full text
REMEC
m o Hybrid Amplifiers c . High Dynamic Range U 4 t e: Electrical Specifications e h S a t a D . w w w
(1)
5 - 500 MHz
Parameter
Specification Limit -55 to +85 5 - 500 +0.8 / -0.4 1.0 25 1.5:1 1.5:1 +11
Units °C MHz dB dB Max dB Max p-p dB Min Max Max dBm Min
QBH-119
Temperature Frequency Range Small Signal Gain Gain vs. Temperature Gain Flatness Reverse Isolation VSWR Input Output 1 dB Compression Output Intercept Point 3rd Order 2nd Order Noise Figure DC Power @ 15 Vdc ± 1% Gain vs. Vdc Housing
+25
15.0 ± 0.5 0.6 25 1.5:1 1.5:1 +12
Notes: 1. Specifications are guaranteed when tested in a 50 Ohm system. Specifications indicated as typical are not guaranteed.
Typical S-Parameter Data
S11 MHz dB Ang 5 -20.5 -168.3 100 -21.5 131.0 200 -19.8 94.5 200 -19.8 94.3 300 -18.4 61.