Datasheet4U Logo Datasheet4U.com

SGE2698-1 - Transformer

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
www.DataSheet4U.com Specification Number SGE2698-1 Rev. B(120401) Rev. C (121801) This Document describes and specifies the electrical and mechanical characteristics of SGE2698-1 inverter transformer for CCFL inverter power supply . This component should be designed and manufactured in accordance with Engineering Specification LES1410T Magnetic Component Specification 1. Electrical Characteristics Items L1-2, L2-3 (uH) L6-5 (mH) LLKG2-4 ,LLKG4-6 (uH) Inductance ( at 10Khz, 0.1V) Min Nom Max Items D.C Resistance Min Nom Max 94 106 118 836 938 1040 Inductance ( at 100Khz, 1Vrms) 5.5 6.0 6.5 Should be shorted pin 6-5 Secondary Self Capacitance C6-5 (pF) 2.0 3.2 5.0 Dielectric Voltage Withstand Secondary to Core 60 Hz.,Arc-detect enabled, 5 sec. min., 200uA max.