Datasheet4U Logo Datasheet4U.com

TTURB2424-15T - DC/DC Transformer

Key Features

  • Power up to 15W.
  • High saturated flux density.
  • Low DCR loss.
  • Class F insulation.
  • SMD package.
  • ER14.5 Bobbin, Dimensions: 14.70 x 16.00 x 6.80mm.
  • Meets EN62368 standards TTURB-15T transformer series feature with 1650VDC primary to secondary isolation, an operating ambient temperature range of -40℃ ~ +125℃. It can be used with our control IC SCM1101AMA to achieve flyback power supply design with an 4:1 wide input volatge range and various protection functions an.

📥 Download Datasheet

Datasheet Details

Part number TTURB2424-15T
Manufacturer MORNSUN
File Size 519.41 KB
Description DC/DC Transformer
Datasheet download datasheet TTURB2424-15T Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
DC/DC Transformer TTURB-15T Series 15W flyback transformer in SMD package 4:1 input voltage range and 1650VDC isolation test voltage RoHS FEATURES  Power up to 15W  High saturated flux density  Low DCR loss  Class F insulation  SMD package  ER14.5 Bobbin, Dimensions: 14.70 x 16.00 x 6.80mm  Meets EN62368 standards TTURB-15T transformer series feature with 1650VDC primary to secondary isolation, an operating ambient temperature range of -40℃ ~ +125℃. It can be used with our control IC SCM1101AMA to achieve flyback power supply design with an 4:1 wide input volatge range and various protection functions and superior EMI performance. Selection Guide Certification Part No.