Features

  • Closed loop (compensated) current transducer using the Hall effect.
  • Printed circuit board mounting. Advantages.
  • Excellent accuracy.
  • Very good linearity.
  • Low temperature drift.
  • Optimized delay time.
  • Wide frequency bandwidth.
  • No insertion losses.
  • High immunity to external interference.
  • Current overload capability.

📥 Download Datasheet

Datasheet Details

Part number LAH125-P
Manufacturer LEM
File Size 540.55 KB
Description Current Transducer
Datasheet download datasheet LAH125-P Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducer LAH 125-P For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. IP N = 125 A Electrical data IP N Primary nominal RMS current 125 A IP M Primary current, measuring range 0 ... ±200 A RM Measuring resistance @ TA = 70 °C TA = 85 °C R R M min M max R R M min M max with ±12 V @ ±125 Amax 0 49 14 48 Ω @ ±200 Amax 0 14 14 15 Ω with ±15 V @ ±125 Amax 22 72 29 70 Ω @ ±200 Amax 22 28 29 29 Ω IS N Secondary nominal RMS current 125 mA NP/NSTurns ratio 1 : 1000 UC Supply voltage (±5 %) ±12 ...