Click to expand full text
Current Transducer HXS 20-NP
For the electronic measurement of currents: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.
IP N = 5, 10, 20 A DUAL PHASE
All data are given with RL = 10 kΩ
Electrical data
IP N
Primary nominal RMS current
IP M
Primary current, measuring range
SN
Nominal sensitivity
Uout
Output voltage (Analog) @ IP
Uref
Reference voltage 1) Output voltage
Output impedance
Load impedance
RL
Load resistance
Rout
Output internal resistance
CL
Load capacitance (±20 %)
UC
Supply voltage (±5 %) 2)
IC
Current consumption @ UC = 5 V
Accuracy - Dynamic performance data
±20
A
±60
A
0.625
V/ IP N
UO E ±(0.625·IP/ IP N) V
2.5 ±0.025
V
typ. 200
Ω
200
kΩ
2
kΩ
<5
Ω
4.