Click to expand full text
Breakover Diodes
i
I
H
IBO VH
V VBO
Applications
lTransient voltage protection l High-voltage switches l Crowbar l Lasers l Pulse generators
Application Note H - 6
Remark: For special selection of more than 2 pieces IXBOD 1-... for every break down voltage of VBO > 2000 V please contact us.
© 2000 IXYS All rights reserved
H-1
Single Breakover Diode
IXBOD 1 -06...10
VBO = 600-1000V IAVM = 0.9 A
VBO Standard V Types
600 ±50 700 ±50 800 ±50 900 ±50 1000 ±50
IXBOD 1 -06 IXBOD 1 -07 IXBOD 1 -08 IXBOD 1 -09 IXBOD 1 -10
A K
Symbol
Conditions Ratings
ID
TVJ = 125°C;
V = 0,8x VBO
20 µA
VBO VBO(TVJ) = VBO, 25°C [1 + KT (TVJ - 25°C)]
IRMS
f = 50 HZ;
Tamb = 50°C
1.4 A
connection pins soldered to printed circuit
(conductor 0,035x2mm)
IAVM 0.9 A
ISM
tp = 0.