The EUP3455 is current mode, step-down switching regulator capable of driving 1.5A continuous load with excellent line and load regulation.

The EUP3455 operates with an input voltage range from 4.75V to 40V and the output voltage is externally set from 0.92V to 15V with a resistor divider.

Key Features

  • 4.75V to 40V Wide Input Operating Range Output Adjustable from 0.92V to 15V Up to 1.5A Output Current Programmable Output Current Threshold Programmable Output Over Voltage Threshold 3µA Low Shutdown Current 0.1Ω Internal DMOS Output Switch Up to 95% Efficiency Fixed 200kHz Switching Frequency Internal Soft Start Secondary Cycle-by-Cycle Current Limit Thermal Shutdown Input Supply Undervoltage Lockout Available SOP-8 Package RoHS Compliant and 100% Lead(Pb)-Free Halogen-Free.

📥 Download Datasheet

Datasheet Details

Part number EUP3455
Manufacturer Eutech Microelectronics
File Size 766.02 KB
Description 200KHz Step-Down Converter
Datasheet download datasheet EUP3455 Datasheet

Full PDF Text Transcription for EUP3455 (Reference)

Note: Below is a high-fidelity text extraction (approx. 800 characters) for EUP3455. For precise diagrams, tables, and layout, please refer to the original PDF.

EUP3455 1.5A,40V,200KHz Step-Down Converter DESCRIPTION The EUP3455 is current mode, step-down switc...

View more extracted text
hing regulator capable of driving 1.5A continuous load with excellent line and load regulation. The EUP3455 operates with an input voltage range from 4.75V to 40V and the output voltage is externally set from 0.92V to 15V with a resistor divider. The output current threshold is programmed by an external resistor. The EUP3455 enters into the CC (constant current) mode when output reaches over current threshold. The OV (over voltage) threshold is programmed by an external resistor divider. The EUP3455 stops switching when output reaches over voltage threshold. Fault condition protection includes secondary cycle-by-cycle current limit and thermal shutdown.