The following content is an automatically extracted verbatim text
from the original manufacturer datasheet and is provided for reference purposes only.
View original datasheet text
•
Features
·50-75W isolated output ·Efficiency to 90% ·300KHz switching frequency ·2:1 input range ·Regulated outputs ·Continuous short circuit protection ·Industry standard half-brick package ·Open frame type option
VQB75- Single Output Brick DC-DC Converter
www.DataSheet4U.com
Input
Input Voltage Range Under Voltage Lockout 24V 18-36V 48V 36-75V 24 Vin power up 17V power down 15.5V 48Vin power up 34V power down 32.5V
(see note 4&5)
Positive Logic Remote ON/OFF Input Filter
PI Type
Output