Datasheet4U Logo Datasheet4U.com

DM7490A - Decade and Binary Counters

Description

Each of these monolithic counters contains four masterslave flip-flops and additional gating to provide a divide-bytwo counter and a three-stage binary counter for which the count cycle length is divide-by-five for the 90A and divideby-eight for the 93A All of these counters have a gated zero reset

Features

  • Y Typical power dissipation 90A 145 m.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
DM5490 DM7490A DM7493A Decade and Binary Counters July 1992 DM5490 DM7490A DM7493A Decade and Binary Counters General Description Each of these monolithic counters contains four masterslave flip-flops and additional gating to provide a divide-bytwo counter and a three-stage binary counter for which the count cycle length is divide-by-five for the 90A and divideby-eight for the 93A All of these counters have a gated zero reset and the 90A also has gated set-to-nine inputs for use in BCD nine’s complement applications To use their maximum count length (decade or four-bit binary) the B input is connected to the QA output The input count pulses are applied to input A and the outputs are as described in the appropriate truth table A symmetrical divide-by-ten count can be obtained from the 9