Description
The 96L02 is a dual TTL monostable multivibrator with trigger mode selection reset capability rapid recovery internally compensated reference levels and high speed capability Output pulse duration and accuracy depend on external timing components and are therefore under user control for each application It is well suited for a broad variety of applications including pulse delay generators square wave generators long delay timers pulse absence detectors frequency detectors clock pulse generators
Features
- Y Y Y Y Y Y Y Y
Retriggerable 0% to 100% duty cycle DC level triggering insensitive to transition times Leading or trailing-edge triggering Complementary outputs with active pull-ups Pulse width compensation for DVCC and DTA 50 ns to % output pulse width range Optional retrigger lock-out capability Resettable for interrupt operations
Connection Diagram
Dual-In-Line Package
Logic Symbol
TL F 10203.
- 2 TL F 10203.
- 1
Order Number 96L02DMQB 96L02FMQB or DM96L02N See NS Package.