Update : 2010.05.15
PRODUCT INFORMATION Sensor for Air quality control
VOCs Sensor
◑ General
- for the detection of Formaldehyde Toluene, Organic Solvent - Semi conductor type,
It is applied detection of VOCs gases (toluene, formaldehyde, benzene, ect.)
◑ Application : Ventilator, Air cleaner, Hood. ◑ Operation range
- Working temperature : -10℃ ~ 50℃ - Working humidity : below saturation point - Storage temperature : -20℃ ~ 80℃
◑ Products characteristics
Product code Package S11 Characteristics Wide detection of VOCs gases Application : Air cleaner, Hood
<& 11
> Worm-up time, PH 5min 350㎽ 3
Output data Analogue (1 ~ 5Volt) Basic circuit
Module
&S11 Standard, Op-amp amplifying -P 1XX Relay output : fixed concentration
Analogue (0.