900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






flex

PKV3325PI Datasheet Preview

PKV3325PI Datasheet

DC/DC converter

No Preview Available !

PKV 3000 I – PKV 5000 I
Key Features
Industry standard DIL24
Wide input voltage range,
9–36 V, 18–72 V
High efficiency 74–83% typical
Low idling power
Full output power up to +75 °C ambi-
ent temperature
Input/Output isolation 1,500 Vdc
MTBF > 650,000 hours at +25 °C
ambient
Basic insulation according to
UL 60950-1
Safety Approvals
DC/DC converter
Input 9-36 and 18-72 Vdc
Output up to 0.5A/3W
Design for Environment
Meets requirements in high-temperature
lead-free soldering processes.
The PKV series of DC/DC power modules is intended for
general use in 12/24 V and 48/60V DC systems. Designed
with MOSFET transistors and 200 kHz switching fre-
quency, they are characterized by high efficiency over a
wide load range, very low quiescent power and an excel-
lent line and load regulation.
The DC/DC power modules are encapsulated in an ep-
oxy filled plastic box. The flammability ratings of the en-
capsulating materials are in conformance with UL 94V-0
and have an adequate thermal conductivity. The materi-
als withstand all normal PBA cleaning methods. Flex is
an ISO 9001/14001 certified supplier.
Datasheet




flex

PKV3325PI Datasheet Preview

PKV3325PI Datasheet

DC/DC converter

No Preview Available !

General
Absolute Maximum Ratings
Characteristics
min
max
Units
TC Case temperature1)
TS Storage temperature
VI Input voltage, 0.1 s max
PKV 3000
PKV 5000
–40
–40
+95
+125
40
80
°C
°C
Vdc
VISO
Isolation voltage
(input to output test voltage)
1,500
Vdc
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute
Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with
one parameter at a time exceeding the limits of Output data or Electrical Characteristics.
If exposed to stress above these limits, function and performance may degrade in an
unspecified manner.
Note:
1) Corresponding typical ambient temperature
range (TA) at full output power is – 40 to +75°C.
Input TA = +25°C, unless otherwise specified
Characteristics
VI Input voltage range
VIoff Turn-off input voltage
Inrush current Peak
I2t
Idling power
VIac Ripple voltage
Conditions
min
TA= – 40 to +75°C
PKV 3000
PKV 5000
9
18
PKV 3000
PKV 5000
Low loss,
low inductive
capacitive source
PKV 3000
PKV 5000
IO = 0
IO = IOmax, BW=20 MHz
typ max Units
36 V
72
8 V
16
35
0.005
0.005
0.3
100
A
A2s
A2s
W
mVp-p
Miscellaneous
Characteristics
Conditions
Input/Output
coupling capacitor
Switching frequency
RH = 48%, TC = +25°C
f = 100 Hz
VI = VInom, IO = IOmax
min
typ
1000
200
max Unit
pF
kHz
Safety
The PKV 3000 I and PKV 5000 I series
DC/DC converters are designed in
accordance with safety standards
UL 60 950-1, Safety of Information
Technology Equipment. The PKV
3000 I and PKV 5000 I series DC/
DC converters are UL 60 950-1
recognized. The DC/DC converter
should be installed in the end-use
equipment, in accordance with
the requirements of the ultimate
application. The input source must be
isolated by minimum Basic insulation
from the primary circuit in accordance
with UL 60 950-1. If the input voltage
to the DC/DC converter is 72 V dc or
less, then the output remains SELV
(Safety Extra Low Voltage) under
normal and abnormal operating
conditions.
It is recommended that a slow blow
fuse with a rating of 2 x IImax be used
at the input of each DC/DC converter.
If a fault occurs in the converter that
imposes a short circuit on the input
source, this fuse will provide the
following functions:
• Isolate the faulty DC/DC converter
from the input power source not to
affect the operation of other parts of
the system.
• Protect the distribution wiring from
excessive current and power loss
thus preventing hazardous overhea-
ting.
The galvanic isolation is verified in an
electric strength test. The test voltage
V(VdIScOf)obre6t0wseeecnoinnpdus.t
and output is 1500
Leakage current is
less than 1µA at nominal input voltage.
The flammability rating for all
construction parts of the DC/DC
converter meets UL 94V-0.
Environmental Characteristics
Test method
Reference
Vibration IEC
(Sinusoidial)
68-2-6
FC
Shock IEC 68-2-27 Ea
( Half-sinus)
Temperature c hange IEC 68-2-14 Na
Test procedure & conditons
Frequency
Amplitude
Accelaration
Number of cycles
Test duration
10...500Hz
0.75 mm
10 g
10 in each axis
1 h per axis
Peak acceleration
Shock duration
200g
3 ms
Temperature
Number of cycles
– 40°C to +125°C
100

28701- BMR 702 Rev. A © Flex, November 2017


Part Number PKV3325PI
Description DC/DC converter
Maker flex
Total Page 21 Pages