Datasheet4U Logo Datasheet4U.com

GTCX25-XXXM-R02 - Gas Discharge Tubes

General Description

No Leads: GTCN25-XXXM-R02 Axial Leads: GTCA25-XXXM-R02 Surface-mount: GTCS25-XXXM-R02 Tray / Reel Standard Package 200pcs 5,000pcs 100pcs 1,000pcs 1,500pcs (Reel) 12,000pcs Part Numbering System Example Part Number: GTCX25-351M-R02 GT = C= X= 2= 5= 351 = M= R= 02 = Gas Tube Ceramic Lead Configu

Key Features

  • 2Pole, 5mm devices.
  • Broad voltage range from 75V-600V.
  • Various form factors: surface mount, axial leads, no leads.
  • Low capacitance and insertion loss.
  • UL 497B recognized.
  • RoHS compliant.
  • Devices tested per ITU K.12 recommendations.
  • Non-radioactive materials.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Gas Discharge Tubes GTCX25-XXXM-R02 Series TE Circuit Protection 5mm 2Pole GDTs (ceramic gas discharge tubes), are commonly used to help protect sensitive telecom equipment such as communication lines, signal lines and data transmission lines from damage caused by transient surge voltages that typically result from lightning strikes and equipment switching operations. Raychem Circuit Protection GDTs offer a high level of surge protection, low capacitance and a broad array of breakover voltage levels, making them suitable for applications such as MDF (Main Distribution Frame) modules, high data-rate telecom applications (e.g. ADSL, VDSL), and surge protection on power lines. Raychem Circuit Protection GDTs, can help equipment meet the most stringent regulatory standards.