900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Teledyne Technologies

C3P24D25C Datasheet Preview

C3P24D25C Datasheet

Three-Phase Output 25A 280 Vac DC control

No Preview Available !

Part Number
C3P24D25
C3P24D25C
Description
25A, 280 Vac
25A, 280 Vac
Part Number Explanation
Series C3P
Three-Phase Output 25A 280 Vac
DC control
www.DataSheet4U.comNOTES
1) Line Voltage (nominal): 24 = 240 Vac
2) Switch Type: D = Zero-cross turn-on
3) Thermal pad available, contact factory
MECHANICAL SPECIFICATION
.500
(12.7)
0.150
(3.81)
MAX 0.140 OF
CERAMIC
0.193
(4.90)
2.8
(71.12)
C3P
TELEDYNE RELAYS THREE POLE
CONTROL
IN
+
AC
POLE
A
A1 A2
AC
POL
B
B1 B2
AC
POLE
C
C1 C2
0.050 X 0.020 THICK
(1.27 X 0.51)
0.325
(8.26)
0.150 TYP.
(3.81)
0.450
(11.43)
3.200
(81.28)
1.090
(27.69)
0.500
(12.70)
FEATURES/BENEFITS
• Three-phase solid-state relay in a compact SIP
package
• High-temperature plastic housing for mechanical
ruggedness
• Tight zero-cross window for low EMI
• Exposed ceramic baseplate for reduced thermal
resistance
DESCRIPTION
The Series C3P three-phase AC solid-state relays
are designed to control medium amounts of power in
three-phase applications. Optical isolation ensures
complete protection of the C3P’s control circuit from
load transients. The C3P’s compact plastic housing
provides a low-cost alternative to large metallic three-
phase contactors. The C3P is designed with
heatsinking in mind. The ceramic baseplate provides
excellent thermal performance. The relay’s tight zero-
cross window greatly reduces EMI.
WEIGHT: 1.093 oz. (31g)
Figure 1 — C3P relay; dimensions in inches (mm)
INPUT (CONTROL) SPECIFICATION
Min Max Units
Control Range
C3P24D25
10 30 Vdc
C3P24D25C
3.5 10 Vdc
Input Current Range
Must Turn-off Voltage
Input Resistance
9 30
1
(See Figure 2)
mA
Vdc
Reverse Voltage
C3P24D25
C3P24D25C
30 V
10 V
APPLICATIONS
• Heating control
• HVAC controls
• Light/Lamp control
• Three-phase AC loads
CONTROL CHARACTERISTIC
35
30
C3P24D25C
25
20
C3P24D25
15
10
5
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Control Voltage (V)
Figure 2 — Control Characteristics
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
C3P 1
C3P\032003\Q1




Teledyne Technologies

C3P24D25C Datasheet Preview

C3P24D25C Datasheet

Three-Phase Output 25A 280 Vac DC control

No Preview Available !

Series C3P
OUTPUT (LOAD) SPECIFICATION
Min Max
Operating Range
24 280
Peak Voltage
600
Load Current Range
.05 25
(See Figure 5)
Maximum Surge Current Rating
(Non-Repetitive, see Figure 4)
250
On-State Voltage Drop
1.08 + (0.016 x I)
www.DataSheet4UZ.ecroom-Cross Window
±12
Off-State Leakage Current (60Hz)
1
Turn-On Time
8.3
Turn-Off Time
8.3
Off-State dv/dt
500
Operating Frequency Range 47
440
I2t for match fusing (<8.3ms)
260
Unit
Vrms
V
Arms
A
V
V
mA
ms
ms
V/µs
Hz
A2S
SURGE CURRENT
250
1 10 100
Number of Equal Amplitude Current Pulses at 60Hz
Figure 4 — Surge Current Curves
ENVIRONMENTAL SPECIFICATION
Min Max
Operating Temperature
–40
100
Storage Temperature
–40 100
Input-Output Isolation
2500
Output-Case Isolation
2500
Rated Impulse Voltage
2500
Unit
°C
°C
Vi
Vi
V
BLOCK DIAGRAM
DETECTION/
CONTROL
CIRCUIT
+
VDC
Input
OPTO
ISOLATED
CONTROL
DETECTION/
CONTROL
CIRCUIT
A1
POLE A
AC
A2
B1
POLE B
AC
B2
THERMAL CHARACTERISTICS
85
80 3 phase
75
70
65
60 2 phase
55
50
45
40
35
30 1 phase
25
20
15
10
5
0
0 2 4 6 8 10 12 14 16 18 20 22 24
Load Current (Arms)
1°C/W
0.75°C/W
85
80
75
1.5°C/W
70
65
60
2°C/W
55
50
45
40
35
4°C/W
30
25
20
15
10
5
0
0 10 20 30 40 50 60 70 80 90 100
Ambient Temperature (°C)
Figure 5 — Current Derating Curves
C3P 2
DETECTION/
CONTROL
CIRCUIT
Figure 3 — Block Diagram
C1
POLE C
AC
C2
NOTES:
1. Electrical specifications at 25°C unless otherwise noted.
2. External MOV or snubber is recommended for transient suppression.
3. For 800Hz applications, contact factory.
4. For additional/custom options, contact factory.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS
C3P\032003\Q1


Part Number C3P24D25C
Description Three-Phase Output 25A 280 Vac DC control
Maker Teledyne Technologies
PDF Download

C3P24D25C Datasheet PDF






Similar Datasheet

1 C3P24D25 Three-Phase Output 25A 280 Vac DC control
Teledyne Technologies
2 C3P24D25C Three-Phase Output 25A 280 Vac DC control
Teledyne Technologies





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy