DATA SHEET • CLA4605-085LF SURFACE MOUNT LIMITER DIODE
Table 1. CLA4605-085LF Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Reverse voltage
VR 60 V
Forward current @ 25 °C
IF
1.5 A
CW power dissipation @ 85 °C
PD
1W
Peak pulse power dissipation @ 85 °C (10% duty cycle)
10 W
Storage temperature
TSTG
–65 +200
°C
Junction temperature
TJ
175 °C
Operating temperature
TA
–40 +150
°C
Electrostatic Discharge:
Charged Device Model (CDM), Class 4
Human Body Model (HMB), Class 1C
Machine Model (MM), Class A
ESD
1000 V
1000 V
150 V
Note: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 2. CLA4605-085LF Electrical Specifications (Note 1)
(TA = +25 °C Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Breakdown voltage
VB IR = 10 A
Reverse current
IR VR = 24 V
Capacitance
CT f = 1 MHz, VR = 6 V
Series resistance
RS f = 500 MHz, IF = 10 mA
Series inductance
LS
Carrier lifetime
TL IF = 10 mA
I region width
W
CW thermal resistance
θJC Junction-to-case
Peak thermal resistance
θP Single 1 μs pulse width,
junction-to-case (10%
duty cycle)
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Min
30
Typical
0.32
1.25
0.3
13
2
91
9
Max
60
1
0.45
2.00
Units
V
μA
pF
Ω
nH
ns
μm
°C/W
°C/W
Table 3. Typical Performance @ 25 °C
Part Number
Insertion Loss
@ –10 dBm
(dB)
Input Power for
1 dB Loss
(dBm)
Maximum Pulsed
Input Power
(dBm)
Output @ Maximum
Pulsed Input
(dBm)
CLA4605-085LF
0.1
+9 +49
+27
Notes:
Limiter power results @ 1 GHz for shunt connected, single limiter diode and DC return in 50 Ω line.
Maximum pulsed power for 1 μs pulse and 0.1% duty factor with chip @ 25 °C heat sink. Derate linearly to 0 W @ 175 °C.
Maximum CW input power @ 25 °C heat sink. Derate linearly to 0 W @ 175 °C.
Recovery time to insertion loss from limiting state.
Maximum CW
Input power
(W)
3
Recovery Time
(ns)
10
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
2 June 13, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201586F