Datasheet4U Logo Datasheet4U.com

S-93C86B - 3-WIRE SERIAL E2PROM

Description

1 CS Chip select input 2 SK Serial clock input 3 DI Serial data input 4 DO Serial data output 5 GND Ground 6 TEST 1 Test 7 NC No connection 8 VCC Power supply

1.

Connect to GND or VCC.

Features

  • Operating voltage range: Read 2.7 V to 5.5 V (Ta =.
  • 40°C to +105°C) Write 2.7 V to 5.5 V (Ta =.
  • 40°C to +105°C).
  • Operation frequency: 1.0 MHz (VCC = 4.5 V to 5.5 V, Ta =.
  • 40°C to +105°C).
  • Write time: 4.0 ms max.
  • Sequential read capable.
  • Write protect function during the low power supply voltage.
  • Function to protect against write due to erroneous instruction recognition.
  • Endurance: 106 cycles/wor.

📥 Download Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
S-93C86B H Series www.sii-ic.com © Seiko Instruments Inc., 2009-2015 FOR AUTOMOTIVE 105°C OPERATION 3-WIRE SERIAL E2PROM Rev.2.1_00 The S-93C86B H Series is a high temperature operation 3-wire serial E2PROM for automotive components. The S-93C86B H Series has the capacity of 16 K-bit, and the organization is 1024-word × 16-bit. It is capable of sequential read, at which time addresses are automatically incremented in 16-bit blocks. The communication method is by the Microwire bus.  Features • Operating voltage range: Read 2.7 V to 5.5 V (Ta = −40°C to +105°C) Write 2.7 V to 5.5 V (Ta = −40°C to +105°C) • Operation frequency: 1.0 MHz (VCC = 4.5 V to 5.5 V, Ta = −40°C to +105°C) • Write time: 4.0 ms max.
Published: |