SMM4F6.0A Overview
The SMM4F Transil series has been designed to protect sensitive equipment against electro-static discharges according to IEC 61000-4-2, MIL STD 883 Method 3015, and electrical over stress such as IEC 61000-4-4 and 5. They are generally for surges below 400 W 10/1000 µs. This planar technology makes it patible with high-end equipment and SMPS where low leakage current and high junction temperature are required to...
SMM4F6.0A Key Features
- Typical peak pulse power
- 400 W (10/1000 µs)
- 2.4 kW (8/20 µs)
- Stand off voltage range: from 5 V to 33 V Unidirectional types Low leakage current
- 0.2 µA at 25 °C
- 1 µA at 85 °C Operating Tj max: 175 °C JEDEC registered package outline RoHS package Halogen free molding pound
- IEC 61000-4-2 level 4
- 15 kV (air discharge)
- 8 kV (contact discharge) MIL STD 883G-Method 3015-7: class3
- 25 kV (human body model)