900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Protek Devices

PLCDA12 Datasheet Preview

PLCDA12 Datasheet

500W MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY

No Preview Available !

Only One Name Means ProTek’Tion™
500 WATT MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY
PLCDA03 - PLCDA24
DESCRIPTION
The PLCDAxx Series are ultra low capacitance multi-line transient voltage suppressor arrays that provides board level
protection for standard TTL and CMOS bus line applications against the damaging effects of ESD, tertiary lightning and
switching transients.
The PLCDAxx Series has a peak pulse power rating of 500 Watts for an 8/20µs waveshape. This device series meets
the IEC 61000-4-2, IEC 61000-4-4 and IEC 61000-4-5 requirements.
SO-8 PACKAGE
FEATURES
Compatible with IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
Compatible with IEC 61000-4-4 (EFT): 40A - 5/50ns
Compatible with IEC 61000-4-5 (Surge): 24A, 8/20µs - Level 2(Line-
Gnd) & Level 3(Line-Line)
500 Watts Peak Pulse Power per Line (tp = 8/20µs)
Bidirectional Configuration
Available in Multiple Voltages Ranging from 3V to 24V
• Protects Two Lines
Ultra Low Capacitance: 5pF
RoHS Compliant
REACH Compliant
MECHANICAL CHARACTERISTICS
Molded JEDEC SO-8 Package
Approximate Weight: 70 milligrams
Lead-Free Pure-Tin Plating (Annealed)
Solder Reflow Temperature:
Pure-Tin - Sn, 100: 260-270°C
12mm Tape and Reel Per EIA Standard 481
Flammability Rating UL 94V-0
APPLICATIONS
Computer Interface Protection
Ethernet - 10/100/1000 Base T
Audio/Video Inputs
• Cellular Phone Terminals
PIN CONFIGURATION
8765
05076.R11 5/18
1234
Page 1
ISO 9001: 2015 CERTIFIED




Protek Devices

PLCDA12 Datasheet Preview

PLCDA12 Datasheet

500W MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY

No Preview Available !

Only One Name Means ProTek’Tion™
TYPICAL DEVICE CHARACTERISTICS
PLCDA03 - PLCDA24
MAXIMUM RATINGS @ 25°C Unless Otherwise Specified
PARAMETER
SYMBOL
Operating Temperature
Storage Temperature
Peak Pulse Power (tp = 8/20µs) - See Figure 1
TL
TSTG
PPP
VALUE
-55 to 150
-55 to 150
500
UNITS
°C
°C
Watts
PART
NUMBER
(Note 1)
ELECTRICAL CHARACTERISTICS PER LINE @ 25°C Unless Otherwise Specified
DEVICE
MARKING
RATED
STAND-OFF
VOLTAGE
MINIMUM
BREAKDOWN
VOLTAGE
MAXIMUM
CLAMPING
VOLTAGE
(Fig. 2)
MAXIMUM
LEAKAGE
CURRENT
MAXIMUM
CAPACITANCE
(Note 2)
VVOWLMTS
@1mA
VVO(LBRT)S
@VIOPV=LCT1SA
@µVIDAWM
@0V, 1MHz
C
pF
PLCDA03
SGA
3.3
4.5
7.0
125
5
PLCDA05
SGB
5.0
6.0
9.8
20
5
PLCDA08
SGF
8.0
8.5 13.4
10
5
PLCDA12
SGC
12.0
13.3
19.0
1
5
PLCDA15
SGD
15.0
16.7
24.0
1
5
PLCDA24
SGE
24.0
26.7
43.0
1
5
NOTES
1. Devices are designed to be used in parallel (see application). For other applications, contact the factory. Do not apply surge in the forward direction of this device.
2. Do not surge from pins 8 to 1, 2 to 7, 6 to 3, and 4 to 5. PIV typically greater than 100V for each rectifier diode. Electrical characteristics apply to pins 1 to 8, 7 to 2, 3 to 6 and 5 to 4.
05076.R11 5/18
Page 2
ISO 9001: 2015 CERTIFIED


Part Number PLCDA12
Description 500W MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY
Maker Protek Devices
PDF Download

PLCDA12 Datasheet PDF






Similar Datasheet

1 PLCDA12 500W MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY
Protek Devices
2 PLCDA15 500W MULTI-LINE ULTRA LOW CAPACITANCE TVS ARRAY
Protek Devices





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy