CERMAX XENON ARC LAMPS

No Preview Available !

Lighting
Imaging
Telecom
Cermax® Xenon Arc Lamps
PE125BF and PE125BUV
CERMAX® XENON ARC LAMPS
Description
The Cermax® xenon arc lamp is an innova-
tive lamp design in the specialty lighting
industry. These lamps were introduced in
the early 1980’s and are now used in endo-
scopes in most major hospitals worldwide,
in high brightness projection display sys-
tems, and for a wide variety of other high
performance applications.
The PE125BF and PE125BUV Cermax®
lamps have an integrated parabolic reflector,
enabling high intensity, focused output of
ultraviolet, visible, and infrared radiation.
With their internal reflector and rugged
ceramic body construction, Cermax® lamps
are the safest and most compact alternative
to conventional quartz xenon lamps. This
makes them ideal for applications that
require a high degree of illumination control.
Current-regulated or power-regulated power
supplies with output ripples of less than 5%
are recommended. Single shot ignition
pulses are advised because radio frequency
starters may damage the lamps internal
reflector.
In addition to lamps, PerkinElmer
Optoelectronics manufactures Cermax® arc
lamp power supplies, lamp holders, OEM
lighting systems, and fiber optic light
sources.
Applications
Medical and industrial fiber optic illu-
minators
Machine vision
Infrared and visible spotlights/beacons
Spectroscopy
Microscopy
UV Curing
Video projection
www.perkinelmer.com/opto
.




PerkinElmer Optoelectronics

PE125BUV Datasheet Preview

PE125BUV Datasheet

CERMAX XENON ARC LAMPS

No Preview Available !

PE125BF and PE125BUV
Operational Specifications
Description
Nominal
Range
Power
125 watts
75-150 watts
Current
12 amps (DC)
7-14 amps (DC)
Operating Voltage 11 volts (DC)
9.5-12.5 volts (DC)
Ignition Voltage 17 kilovolts (recommended minimum)
Temperature
150ºÞ C (maximum)
Lifetime*
1000 hours (500 hour warranty)
* End of lamp life is defined as 50% of initial output.
Output at Nominal Power
F= UV Filtered Output/ UV = UV Enhanced Output
Description
Peak Intensity
Radiant Output*
UV Output*
IR Output*
Visible Output*
Color Temperature
Peak Instabilities
Beam Geometry**
PE125BF
300x103 candelas
17 watts
0.8 watts
10 watts
1500 Lumens
5600 Kelvin
4%
4.5º/5º/6º
PE125BUV
280x103 candelas
17 watts
2.2 watts
9 watts
1350 Lumens
5050 Kelvin
4%
4.5º/5º/6º
*These values indicate total output in all directions.
Wavelengths = UV<390nm, IR>770nm, Visible 390nm to 770nm.
** Beam Geometry defined as half angle at 10% PTS after 01/100/1000 hours.
Dimensions
1.000 (25.4)
.164
(4.19)
.250 (6.35)
.250 (6.35)
1.00
(25.4)
6-32 UNC 2B x .156 DP
3 Holes EQ SP on A
.750 (19.05) BC
2 x .40
(10.2)
1.667
42.34
.035
(.899)
.066 (1.52)
.125 (3.18)
1.298 (32.96)
Y
X
Focal Point
Cathode
Physical Specifications
Description
Arc Gap
Reflector Geometry
Weight
Window Diameter
Specification
.044 inch (1.14mm)
Parabolic Y2 = 0.5 X (inch)
130.8 grams
1 inch (25.4 mm)
Focused Output at F/1.0 Lens
Description
Visible Output
6mm aperture
1050 Lumens
8mm aperture
620 Lumens
* Nominal values at 125 watts after 2 hour burn-in.
Total Output*
9.5 watts
5.6 watts
Notes
1. Lamp must not be operated with window facing upwards within
45º of vertical.
2. Seal temperature must not exceed 150º C.
3. Current/power regulated power supplies and PerkinElmer lamp
housing units are recommended.
4. Lamp must be operated within recommended current and power
range. Over powering may lead to arc instability, hard starting
and premature aging.
5. Hot mirror assembly is available for IR filtering.
6. CERMAX lamps are much safer lamps to use than their quartz
xenon arc lamp equivalents. However, caution must be practiced
when operating lamps because they are under high pressure,
require high voltage, reach temperatures up to 200º C, and their
IR and UV radiation can cause skin burns and eye damage.
Read hazard sheet included with each lamp shipment.
Spectral Output
F UV F + HOT MIRROR
100
80
60
40
20
0
200 300 400 500 600 700 800 900 1000 1100
WAVELENGTH (NM)
PerkinElmer welcomes inquiries about special lamps. We would be pleased to discuss the requirements of your application and the feasibility of
designing a lamp specifically suited to your needs.
For more information e-mail us at opto@perkinelmer.com or visit our web site at www.perkinelmer.com/opto.
All values are nominal; specifications subject to change without notice.
USA:
PerkinElmer Optoelectronics
44370 Christy St.
Fremont, CA 94538
Phone: (510) 979-6500
Fax: (510) 687-1140
Toll Free: (800) 775-6786
Europe:
PerkinElmer Optoelectronics GmbH
Wenzel-Jaksch-Str. 31
65199 Wiesbaden
Germany
Phone: +49 611 492 0
Fax: +49 611 492 369
Asia:
PerkinElmer Optoelectronics
47 Ayer Rajah Crescent #06-12
Singapore 139947
Phone: +65 775 2022
Fax: +65 775 1008
.
© 2000 PerkinElmer inc. All rights reserved.
www.perkinelmer.com/opto
DS-152 Rev C 1101


Part Number PE125BUV
Description CERMAX XENON ARC LAMPS
Maker PerkinElmer Optoelectronics
PDF Download

PE125BUV Datasheet PDF






Similar Datasheet

1 PE125BUV CERMAX XENON ARC LAMPS
PerkinElmer Optoelectronics





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy