CS-series DeviceNet Unit
CS1W-DRM21-V1
A DeviceNet Unit for the CS Series
That Boasts Industry-leading
Performance and Functions
CSM_CS1W-DRM21-V1_DS_E_3_1
CS1W-DRM21-V1
Features
• Allows control of up to 32,000 points (2,000 words) per master, and ensures a high degree of simultaneity between data.
• Can be used as both a master and a slave at the same time.
• Equipped with settings and monitor functions aimed at improving both design and startup efficiency. Achieve maximum performance by using
in combination with a Configurator.
• Files of master and slave settings can be uploaded and downloaded using memory cards, allowing effective debugging and easier setup.
System Configurations
DeviceNet
Configurator
Control system
Maintenance system
PLC
Control
information
Ethernet
DRT2-series
MIL Connector
Terminals
Maintenance information
Common Smart Slave Functions
Network power supply voltage monitor
E5ZN-DRT
Unit/Connected device comments
Smart Slave DeviceNet
Communications Unit
Unit power-ON time monitor DRT2-series
DRT2-series
Remote I/O Terminals
Remote I/O Terminals
Relay Output Terminals
Models with 3-tier
Terminal Blocks
DRT2-series
Smart Slave
Remote I/O Terminals
DRT2-series
Smart Slave
Analog I/O Terminals
DRT2-series
Smart Slave
Environment-resistive
Terminals
DRT2-series
Smart Slave
Sensor Terminals
DRT2-series
Screw-less Clamp
Terminals
Smart Slave:
DRT2-series
Board Terminals
with MIL Connectors
Reduce Setup Time
• Network power supply monitor function • Moving average processing function
• Input filter function
• Power-ON inrush current
protection function
• Number of A/D conversion points
(conversion cycle) setting
• Peak/bottom hold function
• Communications speed
auto-detect function
• Scaling function
• Top/valley hold function
• Percentage change calculation
function
• User compensation function
• Cumulative counter
Reduce Downtime
• Unit comments function
• Connected device comments function
• I/O power supply monitor function
• Sensor power supply short-circuit detection function
• External load short-circuit detection function
• Disconnected sensor detection function
Improve Maintenance
• Operation time monitor function
• Contact operations counter (See note.)
• Unit conduction time monitor function
• Total ON time monitor function (See note.)
• Network power supply voltage monitor function
• Communications error log function
• Last maintenance date
• Comparator function
• Selectable output value after error
Note: The number of contact operations monitor function and the cumulative ON time monitor function cannot be used simultaneously for the same
contact.
1