900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Nortech

PD130 Datasheet Preview

PD130 Datasheet

(PD130 / PD139) Single Channle Loop Detectors

No Preview Available !

PRODUCT DATA
www.nortechcontrol.com
Single Channel Loop Detectors
PRODUCT DESCRIPTION
One of the most critical components of the whole vehicle access control
system is the inductive loop detector. Nortech’s detectors have been
renowned for their reliability and durability for many years.
Single channel loop detectors are used to identify the presence of vehicles
by means of an inductive loop buried under the road. These “single chip”
microprocessor-based units benefit from a detect filter and frequency
indicator and are suitable for parking control and motorised door or gate
applications all detectors are CE tested and approved.
A compact detector diagnostic unit is available for extracting data from new
and existing sites.
FEATURES
PD130 - Vehicle Detector
Compact size
Diagnostic capabilities
Selectable permanent presence
Loop isolation protection
Loop frequency indication
Automatic Sensitivity Boost (ASB)
Detect filter
PD139 - Card Based Vehicle Detector
Compact size
www.D ataDSihaegento4sUti.ccocmapabilities
Selectable permanent presence
Loop isolation protection
Loop frequency indication
Automatic Sensitivity Boost (ASB)
Selectable relay output configuration
Loop fault monitor
Applications
Parking barrier control
Rising bollards
Motorised gates and doors
Industrial control systems
Rising kerbs
High-speed rapid roll industrial doors
GD100 - Vehicle Detector
Compact size
Selectable permanent presence
Selectable presence output (Fail
Safe / Fail Secure)
Loop isolation protection
Visual output LED (fault monitor)
DU100 - Detector Diagnostics Unit
Compact, self-contained test
Exclusive optical readout
No service disruption
Loop diagnosis
Historical data available
Unique crosstalk monitor
PD139
DU100
ISSUE 03




Nortech

PD130 Datasheet Preview

PD130 Datasheet

(PD130 / PD139) Single Channle Loop Detectors

No Preview Available !

Technical Details
Single Channel Loop Detectors
Face-plate LED Indicators:
Red - power,
Green - channel indicator:
1. Tuning - on steady followed by
flashing frequency count (x 10kHz)
2. Undetect - off
3. Detect - on steady
4. Fault - on with short off
Operating Modes:
1. Limited presence/permanent presence
2. Pulse on detect/pulse on undetect
3. Automatic sensitivity boost off/on
4. Filter off/on (2 second delay)
Pulse
PD130
ON
OUTPUT
MODE
PRES
PULSE
FILT
ASB
SENS
FREQ
RESET
Presence
567
48
39
2 10
1 11
NL
Power
PD139
SW1
RSET
PIN 10
PIN 1
1
Presence
2
3
4 Pulse
5
6 Ext Reset
7 + DC
8 - DC
9
10
GD100
+24V DC or 24V AC
0V DC or Nuetral AC
123
8
7
GD 100
654
Presence Pulse
Specifications
PD130/PD139
Self tuning range:
Sensitivity:
Frequency:
20-1500mH
4 step adjustable:
High: 0.02% DL/L; Medium High:
0.05% D L/L; Medium Low: 0.1%
DL/L; Low: 0.5% DL/L
4 step adjustable, 12-80kHz (fre-
quency determined by loop geom-
etry)
PD130 Output Relays:
www .DataSheet4U.com
PD139 Output Relay:
Presence output relay - Change-over
contacts (fail-safe) rated at 5A @
230V AC
Pulse output relay - Change-over
contacts (non-fail-safe) rated at 5A
@ 230V AC
Presence output relay - Change-over
contacts (fail-safe) rated at 1A @
230V AC
Pulse output relay - Change-over
contacts (non-fail-safe) rated at 1A @
230V AC
PD130 Pulse output duration: Approx. 150ms, factory option
250ms
PD139 Pulse output duration: Approx. 150ms
Presence time:
1 hour for 3% DL/L, permanent pres-
ence option
Protection:
Loop isolation transformer,
zener diode clamping on loop inputs
and gas discharge tube protection
PD130 Power requirements:
PD139 Power requirements:
120V AC +/- 15% 48-60Hz (PD131)
230V AC +/- 15% 48-60Hz (PD132)
12-24V AC/DC +/- 15% (PD134)
Requirement: 1.5VA max @ 230V
24V AC/DC +/- 15%
Requirement: 1.1VA max @ 24V DC
Operating temp range:
Material:
Dimensions (mm):
Mounting:
Connector:
Option:
-40oC to +80oC (circuit sealed
against condensation)
PD130: High heat ABS blend
PD130: 76 x 40 x 78; PD139: 105 x
68
PD130: Shelf or DIN-rail socket;
PD139: Panel or plug-in
PD130: Single rear mount 11-pin
submagnal (86CP11); PD139: Molex
10-pin female
Flying leads
Ordering Information
PD131:
PD132;
PD134:
PD139:
PD139-FAAC:
Single channel, boxed, 120V AC
Single channel, boxed, 230V AC
Single channel, boxed, 12-24 V AC/DC
Single channel, PCB, 24V DC
Single channel, PCB, designed to fit FAAC
barrier controllers
PD132-PFM
GD100:
DU100
Single channel, boxed, 320V AC with power
fail memory
Single channel DIN rail mount detector, 24V
AC/DC
Detector diagnostic unit
Nortech Control Systems Limited • 42 Llantarnam Business Park • Cwmbran • South Wales • NP44 3AW
Phone: +44(0)1633 485533 • Fax: +44(0)1633 485666 • email: info@nortechcontrol.com • Web: www.nortechcontrol.com


Part Number PD130
Description (PD130 / PD139) Single Channle Loop Detectors
Maker Nortech
PDF Download

PD130 Datasheet PDF






Similar Datasheet

1 PD130 (PD130 / PD139) Single Channle Loop Detectors
Nortech
2 PD1303YVS MOSFET
UNIKC
3 PD139 (PD130 / PD139) Single Channle Loop Detectors
Nortech





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z



Site map

Webmaste! click here

Contact us

Buy Components