CD288/CD288H SERIES
AALUMINUM ELECTROLYTIC CAPACITORSS
● Load life of 1000 hours at 85℃
● CD 288H: Load life of 1000 hours at 105℃
● High frequency and low impedance
■ SPECIFICATIONS
Item
Operating Temperature Range(℃)
Rated Voltage Range (V)
Nominal capacitance range (μF)
Capacitance Tolerance(20℃,120Hz)
Leakage current (μA)
Characteristics
-40~+85(CD288H: -40~+105)
-25~+85(CD288H: -25~+105)
10~100
160~250
4.7~3300
±20%
I≤0.01CV (at 20℃ ,after 2minutes)
I≤0.03CV (at 20℃ ,after 2minutes)
C: Nominal Capacitance (μF) V: Rated Voltage (V)
Dissipation Factor(20℃,120Hz)
Rated Voltage (V)
10 16 25 35 50 63 100 160~250
tanδ 0.20 0.16 0.14 0.12 0.10 0.09 0.08 0.15
when nominal capacitance is over 1000uF tanδ shall be added 0.02 to the listed
value with increase of every 1000μF
Temperature Stability(120Hz)
Rated voltage (v)
Impedance Ratio
Z-40℃/Z+20℃
Z-25℃/Z+20℃
10~16
5
-
25~100
4
-
160
-
4
250
-
7
Load Life(+85℃,CD288H:+105℃)
Shelf Life(+85℃,CD288H:+105℃)
■ DIMENSIONS
Time
Leakage Current
Capacitance Change
Dissipation Factor
1000 hours.
Not more than the specified value.
Within ±20% of the initial value.
Not more than 200% of the specified value.
Time
500 hours.
Leakage Current
Not more than the specified value.
Capacitance Change
Within ±20% of the initial value.
Dissipation Factor
Not more than 200% of the specified value.
After test: Rated voltage to be applied for 30 minutes, 24 to 48 hours before measurement.
MM
Lead spacing and diameter
ΦD±1.0
F±0.5
Φd±0.1
a
12.5
5.0
0.6
16
7.5
0.8
0~+2.0
18
7.5
PAGE 1 OF 2