SA40011
SA40011 is Dual Axis Signal Conditioning Module manufactured by My Line.
features overload protection, and is 100% reliability tested to provide the highest quality available.
General Specifications
Input voltage …………....+/-10 to +/-16Vdc Input current ………….... 12m A Sensor excitation ..……….... 10 V pp, square wave Input impedance ...……….... 5 megohms Output ……………… +/-7Vdc @ +/-10Vdc input Time constant .……… 150 msec Offset adjustment …… +/-1Vdc Output ripple ……… 0.2% / Vdc output Temperature coefficients (module w/out sensor) O
- Null …….….... 60 microvolts / C (typical) O
- Scale .……...… 0.02% / C Output short duration .… Continuous Temperature range O
- Operating …… -20 to +70C O
- Storage ..…….…... -40 to +80C Temperature pensation
- Temperature pensation of the assembly (module and sensor) can be acplished using an external silicon temperature sensor (KTY81-120) and resistor (47k ohm typical). With this configuration, it is possible to reduce the scale O O temperature coefficient error from a 0.3%/C (nominal), to 0.03%/C (nominal). Please see wiring diagram for connection points.
Dimensions
SPECTRON SYSTEMS TECHNOLOGY INC.
595 OLD WILLETS PATH HAUPPAUGE NY 11788 PHONE: 631 582-5600 FAX: 631 582-5671 Specifications are subject to change without notice! Doc.# SDS-106-0405
- Dual Axis Signal Conditioning Module
Input/Output Connections
Consult factory for further technical information and ordering details!
SPECTRON SYSTEMS TECHNOLOGY INC.