HO60-NP - Current Transducer

Features

  • Open loop multi-range current transducer.
  • Voltage output.
  • Single power supply +5 V.
  • Overcurrent detect 2.93 × IP N (peak value).
  • EEPROM Control.
  • Galvanic separation between primary and secondary circuit.
  • Low power consumption.
  • Compact design for THT PCB mounting.
  • Factory calibrated.
  • Dedicated parameter settings available on request (see page 10). Advantages.
  • Low offset drift.

📥 Download Datasheet

Datasheet Details

Part number HO60-NP
Manufacturer LEM
File Size 1.30 MB
Description Current Transducer
Datasheet download datasheet HO60-NP Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Current Transducer HO-NP series IP N = 40, 60, 120, 150 A Ref: HO 40-NP, HO 60-NP, HO 120-NP, HO 150-NP For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features ●● Open loop multi-range current transducer ●● Voltage output ●● Single power supply +5 V ●● Overcurrent detect 2.93 × IP N (peak value) ●● EEPROM Control ●● Galvanic separation between primary and secondary circuit ●● Low power consumption ●● Compact design for THT PCB mounting ●● Factory calibrated ●● Dedicated parameter settings available on request (see page 10). Advantages ●● Low offset drift ●● Over-drivable Vref ●● 8 mm creepage /clearance ●● Fast response.
Published: |