NJM2386
NJM2386 is LOW DROPOUT VOLTAGE REGULATOR WITH ON/OFF CONTROL manufactured by New Japan Radio.
- Part of the NJM2388 comparator family.
- Part of the NJM2388 comparator family.
DESCRIPTION
The NJM2386/88 is a general purpose low dropout voltage regulators with ON/OFF control. The output current is up to 1.0A and dropout voltage is 0.2V typical at 500m A load. It features high maximum input voltage of 35V for a wide application range including TV, home appliances and power modules. PACKAGE OUTLINE
NJM2386DL3
NJM2388F
FEATURES
High Maximum Input Voltage Up to 35V Low Dropout Voltage 0.2V typ. at Io=0.5A Output Current Io(max.)=1.0A ON/OFF Control (Active High) Internal Short Circuit Current Limit Internal Overvoltage Protection Internal Thermal Overload Protection Bipolar Technology Package Outline TO-252-5(NJM2386), TO-220F-4(NJM2388) PIN CONFIGURATION
123 45
PIN FUNCTION 1. VIN 2. ON/OFF CONTROL 3. VOUT 4. N.C. 5. GND
PIN FUNCTION 1. VIN 2. VOUT 3. GND 4. ON/OFF CONTROL
123 4
NJM2386DL3 EQUIVALENT CIRCUIT
NJM2388F
VIN CONTROL
Overvoltage Protection
VOUT
ON/OFF Control
Bandgap Reference Thermal Protection Current Limit
Ver.2007-02-23
-1-
NJM2386/88
..
OUTPUT VOLTAGE RANK LIST Device Name VOUT NJM2386DL3-33 3.3V NJM2386DL3-05 5.0V NJM2386DL3-63 6.3V NJM2386DL3-08 8.0V NJM2386DL3-09 9.0V NJM2386DL3-12 12.0V
Device Name NJM2388F33 NJM2388F05 NJM2388F63 NJM2388F08 NJM2388F84 NJM2388F09 NJM2388F10 NJM2388F12
VOUT 3.3V 5.0V 6.3V 8.0V 8.4V 9.0V 10.0V 12.0V (Ta=25°C) UNIT V V A
RATINGS +35 +35(- 1) 1.0 NJM2386 10(Tc≤25°C) / 1(Ta≤25°C) Power Dissipation PD W NJM2388 18(Tc<50°C) Operating Junction Temperature Range Tj -40 ∼ +150 °C Operating Temperature Range Topr -40 ∼ +85 °C Storage Temperature Range Tstg -50 ∼ +150 °C (- 1): When input voltage is less than +35V, the absolute maximum control voltage is equal to the input voltage.
ABSOLUTE MAXIMUM RATINGS PARAMETER Input Voltage Control Voltage Output Current
SYMBOL VIN VCONT Io
ELECTRICAL CHARACTERISTICS (VIN=VO+1V, Io=0.5A, CIN=0.33µF, Co=22µF, Ta=25°C) Measurement is to be conducted is pulse testing. PARAMETER SYMBOL CONDITIONS MIN. TYP. MAX. UNIT Output Voltage Vo...