Datasheet4U Logo Datasheet4U.com

PLA193 - Normally Open OptoMOS Relay

Description

IXYS Integrated Circuits' PLA193 is a single-pole, norm

Features

  • PLA193E is 100% Tested for Partial Discharge: DIN EN 60747-5-5.
  • 5000Vrms Input/Output Isolation.
  • Low Drive Power Requirements.
  • High Reliability.
  • Arc-Free With No Snubbing Circuits.
  • No EMI/RFI Generation.
  • Small 6-Pin Package.
  • Flammability Rating UL 94 V-0.

📥 Download Datasheet

Full PDF Text Transcription

Click to expand full text
INTEGRATED CIRCUITS DIVISION Parameters Blocking Voltage Load Current On-Resistance (max) LED Current to Operate Ratings 600 100 50 5 Units VP mArms / mADC  mA Features • PLA193E is 100% Tested for Partial Discharge: DIN EN 60747-5-5 • 5000Vrms Input/Output Isolation • Low Drive Power Requirements • High Reliability • Arc-Free With No Snubbing Circuits • No EMI/RFI Generation • Small 6-Pin Package • Flammability Rating UL 94 V-0 Applications • Instrumentation • Multiplexers • Data Acquisition • Electronic Switching • I/O Subsystems • Meters (Watt-Hour, Water, Gas) • Medical Equipment—Patient/Equipment Isolation • Security • Aerospace • Industrial Controls Pin Configuration AC/DC Configuration 1 + Control 2 - Control 3 NC 6 Load 5 Do Not Use 4 Load DC Only Configuration 1 + Contr