The following content is an automatically extracted verbatim text
from the original manufacturer datasheet and is provided for reference purposes only.
View original datasheet text
INTEGRATED CIRCUITS DIVISION
Parameter
Load Voltage Load Current
AC/DC DC-Only On-Resistance (max) Input Control Current
Rating 60
300 600 5.6 1.1
Units VP
mArms/mADC mADC mA
Features
• Fast Turn-On: 100s max with recommended values of CEXT 250s max with no CEXT
• Active Current Limiting • Thermal Shutdown • 1.1mA Input Control Current • Linear AC or DC Operation • High Surge Capability • Low Power Consumption • Clean, Bounce-Free Switching • Surface Mount Version Available • Tape & Reel Packaging Available
Applications
• Security • Instrumentation • Battery Powered Systems • Transportation, Railroad Controls • 12V, 24V Systems
Approvals
• UL 508 Approved Component: File # E69938
Figure 1.