C4900 Datasheet Text
HIGH VOLTAGE POWER SUPPLY UNIT
C4900 SERIES
The C4900 series are pact PC- board mountable high voltage power supplies, especially designed for photomultiplier tubes. The design offers better performance and improved fail- safe protection. The C4900 and- 01 output negative polarity and the C4900- 50 and
- 51 output positive polarity high voltages. PATENT
Features pact and Lightweight High stability Low Power Consumption Fast Response Wide Variable Output Range Ample Protective and Fail- safe Functions
SPECIFICATIONS
Parameter Input Voltage Range Input Current a Variable Output Range Specification Guaranteed Output Voltage Range Output Current b Line Regulation against ±1 V or 0.5 V Change b Load Regulation against 0 % to 100 % Load Change a Ripple / Noise (p-p) b Output Voltage Controlling Modes Controlling Voltage Input Impedance Reference Voltage Output Output Voltage Setting (Absolute value) Output Voltage Rise Time (0 % Temperature Coefficient b Operating Temperature Range Storage Temperature Range Dimensions (W × H × D) Weight Protective Functions a At Maximum Output Voltage. b
C4900 +15 ± 1 with no load with full load 14 90
C4900-01 +12 ± 0.5 15 95 0 to
- 1250
C4900-50 +15 ± 1 14 90
C4900-51 +12 ± 0.5 15 95
Unit V mA (Typ.) V V
0 to +1250 +200 to +1250 0.6 ± 0.01 ± 0.01 0.007 0.5
- 200 to
- 1250 0.6 0.5 mA (Max.) % (Typ.) % (Typ.) % (Typ.) kΩ (Typ.) V (Typ.) V (Typ.) ms (Typ.) %/ °C (Typ.) °C °C mm g
By external controlling voltage (0 V to +5 V) or external potentiometer (50 kΩ ± 2.5 kΩ) 80 +5.13 (with 50 kΩ external potetiometer) (Controlling voltage × 250) ± 0.5 % 50 ± 0.01 0 to +50 -20 to +70 46 × 24 × 12 31
Units protected against reversed power input, reversed/excessive controlling voltage input, continuous overloading/short circuit in output b