PROXIMITY SWITCH
Description
The sensors provide excellent results even with difficult-to-detect objects, e.g. small or thin parts, wires or bright metals.
A variety of types cover a wide range of individual requirements and installation situations. Thus, devices are available with N.C. or
N.O. functions, with NPN or PNP switching outputs, and cable or plug connection.
The enclosure rating is IP66.
Features
Easy-to-use and tough
Wide range of models
Wide operating voltage range
Short circuit protected
Ideal for a variety of applications
With a metal connector that can be tightened securely
and a cord protector
Enclosure rating of IP66, water-proof and oil-drip proof
Fast response
Specification
Item
Differential travel
Target
Power supply voltage
(operating voltage range)
Current consumption (DC 3-wire)
Output type
Control
output
Load current
(See note 1.)
Residual voltage
Operation mode
(with sensing object approaching)
Protection circuit
Ambient air temperature
Temperature influence (See note 1.)
Ambient humidity
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Standards and listings
Standard
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous
metal.)
12 ~ 24 VDC. Ripple (p~p): 10% max.
(10 ~ 30 VDC)
10 mA max.
See Product selection
200 mA max. (32 VDC max.)
1 V max. (under load current of 200 mA with cable length of 2 m)
See Product selection
Output reverse polarity protection, Power source circuit reverse
polarity protection,
Surge suppressor, Short-circuit protection
Operating: -40 to 70 , Storage: -40 to 85 (with no icing or
condensation)
±10% max. of sensing distance at 23 within temperature range
of -25 to 70
±15% max. of sensing distance at 23 within temperature range
of -40 to 70
Operating: 35% to 95%, Storage: 35% to 95%
±1% max. of sensing distance in rated voltage range ±15%
50 Mȍ min. (at 500 VDC) between current carry parts and case
1,000 VAC at 50/60 Hz for 1 min between current carry parts and
case
10 to 55 Hz, 1.5mm double amplitude for 2 hours each in X, Y
and Z directions
1,000 m/s2, 10 times each in x, Y and Z directions
IEC60529: IP66, Degree of protection
EN60947-5-2: EMC
Note : When using any model at an ambient temperature between -40°C and -25°C and a power voltage
between 30 and 32 VDC, use a load current of 100 mA max.,
HIGHLY
D1
Design, specifications are subject to change without notice.