900,000+ datasheet pdf search and download

Datasheet4U offers most rated semiconductors data sheet pdf






Clare .

FR2 Datasheet Preview

FR2 Datasheet

Dyad

No Preview Available !

Dyad®
FR2
Features
Small size
SMT-compatible
Easily formed leads
Sputtered ruthenium contacts
Hermetically sealed contacts
Fast switching speed — up to 500Hz
Wide range of available magnetic sensitivities
Description
Clare’s DYAD® dry reed switches are ideally suited for
small switching signal applications. This switch has
sputtered ruthenium contacts and an extraordinary seal
strength, achieved by a patented laser sealing of the glass.
In low level or dry switching environments, both switches
typically provide >1 billion operations. The switches have
hermetically sealed contacts and offer a wide range of
available magnetic sensitivities.
Applications
Security
Proximity sensing
Smoke alarms
Automotive
Level sensor
Lamp current sensor
Relays
Ordering Information
A complete part number is represented by the digits to the right. For example, FR2S1030 is a
DYAD® with a minimum operate value of 10 and a maximum of 30. Refer to the switch operating
specification charts for available ranges. Special ranges are available upon request.
FR2 S XX XX
Minimum Operate Value (NI)
Maximum Operate Value (NI)
Approvals
UL listed
Standard Test Coil
The magnetic force (expressed in NI, AT or Ampere Turns) required to cause the reed switch contacts to
close is called the pull-in or operate value.
FR2
Part #
Coil definition
Coil resistance
Number of turns
Wire size (nom. diameter)
Bobbin diameter (inside coil)
Winding length
Coil - 1
NARM1 CTC01
1200
5,000
0.0399mm (AWG 46)
3.96mm
10.4mm
(1) Consult factory for test procedure.
The reed switch shall be placed in the test coil with the gap centered in the core of the coil winding.
Test leads and their clips must be non-magnetic.
The longitudinal axis of the test coil and the test switch shall be vertical.
Surface Mount Dyad
Refer to operating characteristics table for complete part number.
DYAD®
Part # Operate Range (NI)1
FR2S1015
FR2S1020
FR2S1030
FR2S1520
FR2S1525
FR2S2025
10 to 15
10 to 20
10 to 30
15 to 20
15 to 25
20 to 25
DYAD® Surface Mount
Part # Operate Range (NI)1,2,3
FR2024
10 to 15
FR2259
10 to 20
FR2282
10 to 30
FR2025
15 to 20
FR2249
15 to 25
FR2026
20 to 25
1 Tolerance = ± 1.5NI
2 Full Blade Sensitivity
3 Surface Mount Switches are packaged 3,000 parts per reel
DS-FR2-R2
www.clare.com
1




Clare .

FR2 Datasheet Preview

FR2 Datasheet

Dyad

No Preview Available !

Dyad®
FR2
Ratings (@ 25˚ C)
Parameter
Min
Switching Voltage
FR2 - DYAD®
Switching Current
FR2 - DYAD®
Carry Current
FR2 - DYAD®
Switching Frequency
FR2 - DYAD®
Contact Resistance
FR2 - DYAD®
(See detailed specifications for more information.)
Typ Max Units
200 Volts
0.5 Amps
1.5 Amps
500 Hz
150 m
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for extended period may degrade the device and effect
its reliability.
Specifications
All parameters are at 25°C unless otherwise stated.
PARAMETER
CONDITIONS
SYMBOL MIN
Contact Ratings
Operate ampere turns range
Full Blade Tolerance = ± 1.5NI
AT
10
Release ampere turns range
Full Blade Tolerance = ± 1.5NI
AT
5
Switching Voltage
Switching Current
Carry Current
Contact Rating
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
VL
IL
I
C
-
-
-
-
-
Life Expectancy
1V, 10mA Signal Level
--
10V, 10mA Low Level
--
50V, 100mA Telecom Load
-
-
100V, 100mA Rated Loads
-
-
Static Contact Resistance
50mV, 10mA(1)
CR -
Contact Material
--
Switch Specifications
Insulation Resistance(2)
100V, 25°C, 40% RH
IR 109
Capacitance
Across Open Contacts
--
Dielectric Strength(5)
Between Contacts
- 250
Operate Time,
including bounce
At nominal coil voltage, TOP -
10Hz Square Wave
Release Time
Environmental Ratings
Zener-Diode Suppression(3)
T
REL
-
Storage Temperature
Operating Temperature
Soldering Temperature
TA -40
TO -40
--
Vibration Resistance
5Hz - 200Hz
G-
Shock Resistance
Weight
11±1ms,
1/
2
Sine
Wave
S-
--
(1) Contact resistance measured with 4 terminal method, 1.1" between test leads
(2) >1012 is available upon request
(3) A 24V zener in series with a diode across the coil
(4) Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare Engineering for more details/recommendations
(5) 15 ampere turn minimum
TYP
-
-
-
-
-
-
1000
500
2
2
80
Ru
1011
0.3
300
-
-
-
-
-
-
-
0.13
MAX UNITS
30 NI
30 NI
200 VDC
500 mAmps
1.5 Amps
10 VA
- x106 Ops
- x106 Ops
- x106Ops
- x106 Ops
150 m
--
-
- pF
- VDC/Peak AC
0.5 ms
0.2 ms
+125
+125
+240
20
100
-
°C
°C
°C
Gs
Gs
grams/unit
2
www.clare.com
Rev. 2


Part Number FR2
Description Dyad
Maker Clare .
Total Page 5 Pages
PDF Download

FR2 Datasheet PDF

View PDF for Mobile








Similar Datasheet

1 FR-A530 Radio Receive
Aiwa
2 FR-E510W-xxK-NA Transistorized Inverter
Mitsubishi
3 FR-E510W-xxK-NA Variable Frequency Drives
Mitsubishi
4 FR-E520-1.5K-NA Variable Frequency Drives
Mitsubishi
5 FR-E520-xxK-NA Transistorized Inverter
Mitsubishi
6 FR-E520-xxK-NA Variable Frequency Drives
Mitsubishi
7 FR-E540-xxK-NA Transistorized Inverter
Mitsubishi
8 FR-E540-xxK-NA Variable Frequency Drives
Mitsubishi
9 FR-E560-xxK-NA Variable Frequency Drives
Mitsubishi





Part Number Start With

0    1    2    3    4    5    6    7    8    9    A    B    C    D    E    F    G    H    I    J    K    L    M    N    O    P    Q    R    S    T    U    V    W    X    Y    Z

Site map

Webmaste! click here

Contact us

Buy Components

Privacy Policy