ADAS1000-2 - Five Electrode Electrocardiogram (ECG) Analog Front-End

Download the ADAS1000-2 datasheet PDF. This datasheet also covers the ADAS1000 variant, as both devices belong to the same five electrode electrocardiogram (ecg) analog front-end family and are provided as variant models within a single manufacturer datasheet.

General Description

The ADAS1000/ADAS1000-1/ADAS1000-2 measure electro cardiac (ECG) signals, thoracic impedance, pacing artifacts, and leadon/lead-off status and output this information in the form of a data frame supplying either lead/vector or electrode data at programmable data rates.

Key Features

  • Biopotential signals in; digitized signals out.
  • 5 acquisition (ECG) channels and one driven lead.
  • Parallel ICs for up to 10+ electrode measurements.
  • Primary ADAS1000 or ADAS1000-1 used with secondary ADAS1000-2.
  • AC and dc lead-off detection.
  • Internal pace detection algorithm on 3 leads.
  • Support for user’s own pace.
  • Thoracic impedance measurement (internal/external path).
  • Selectable reference lead.
  • Scalable noise vs. power control, power-down mod.

📥 Download Datasheet

Note: The manufacturer provides a single datasheet file (ADAS1000_AnalogDevices.pdf) that lists specifications for multiple related part numbers.

Datasheet Details

Part number ADAS1000-2
Manufacturer Analog Devices
File Size 3.72 MB
Description Five Electrode Electrocardiogram (ECG) Analog Front-End
Datasheet download datasheet ADAS1000-2 Datasheet

Full PDF Text Transcription (Reference)

The following content is an automatically extracted verbatim text from the original manufacturer datasheet and is provided for reference purposes only.

View original datasheet text
Data Sheet ADAS1000/ADAS1000-1/ADAS1000-2 Low Power, Five Electrode Electrocardiogram (ECG) Analog Front End FEATURES ► Biopotential signals in; digitized signals out ► 5 acquisition (ECG) channels and one driven lead ► Parallel ICs for up to 10+ electrode measurements ► Primary ADAS1000 or ADAS1000-1 used with secondary ADAS1000-2 ► AC and dc lead-off detection ► Internal pace detection algorithm on 3 leads ► Support for user’s own pace ► Thoracic impedance measurement (internal/external path) ► Selectable reference lead ► Scalable noise vs. power control, power-down modes ► Low power operation from ► 11 mW (1 lead), 15 mW (3 leads), 21 mW (all electrodes) ► Lead or electrode data available ► Supports AAMI EC11:1991/(R)2001/(R)2007, AAMI EC38 R2007, EC13:2002/(R)2007, IEC60601-1 ed. 3.